If you keep topping your boiler pressure back up to around 1–1.5 bar, something is letting water out or the system can't cope with expansion. Repressurising treats the symptom – here's how to find the cause.
A leak somewhere in the system
Check radiator valves, exposed pipework and around the boiler for drips, damp patches or white crusty deposits. Leaks under floors are harder to spot – a boiler losing pressure with no visible leak often needs leak detection.
The pressure relief valve
This safety valve releases water when pressure gets too high. Look for a small copper pipe from the boiler to the outside wall – if it drips after the heating runs, the valve may be faulty or the system is over-pressurising.
A failed expansion vessel
The expansion vessel absorbs the extra volume when water heats up. If it loses its charge, pressure rises when the heating is on and falls when it cools, often causing the relief valve to discharge.
Recently bled radiators
Bleeding radiators releases air and drops the pressure slightly. One top-up afterwards is normal; repeated drops are not.
When to call an engineer
If you need to top up more than once every few weeks, call a qualified engineer. Internal boiler components should only be worked on by a professional.